A conventional Microprocessor fire alarm control panel (FACP) is a core component of a fire alarm system, designed to monitor and control fire detection devices within a building. A fire alarm control panel (FACP) is the central component of a fire alarm system. It’s designed to monitor inputs from fire detection devices and, upon detecting signs of fire or smoke, initiates appropriate responses to alert occupants and authorities through Auto dialer. FACP divides a building into zones, each connected to a circuit where fire detection devices (smoke detectors, heat detectors, manual pullstations) are installed. Each zone represents a specific area of the building. It constantly monitors these zones for any signs of fire or smoke. When a detector is triggered, it identifies the specific zone where the alarm originated, providing crucial information for responders. When a detector is activated, the FACP triggers audio and visual alarms, typically sirens, bells, or strobe lights. FACP often includes manual controls, allowing authorized individuals to silence alarms or perform system tests to ensure proper functioning to ensure continuous operation during power outages, fire alarm control panels usually have a backup power source, commonly in the form of batteries. Conventional fire alarm control panels are simple in their operation, suitable for smaller buildings or installations where a more straight forward alarm system suffices.

MCN-RTC
VARIANTS AVAILABLE
  1. 02 zone, 04 zone with zone voltage of 24v, it works on single 12v battery. The above variant is for small installations, system works on single battery to reduce the recurring cost of battery at the same time the zone voltageis 24v DC as per ISI 2189 standards.
  2. 06 zone, 08 zone, 12 zone,16 zone, 20 zone, 24 zone, 28 zone and 32zone available in 24 volts only

Specifications

Our panel has the following features with very friendly user interface. It maybe noted these are standard features as per the industry requirement but can be modified as per the client/customer requirement.

  1. Rugged CRCA sheet with powder coated finish.
  2. Modular construction.
  3. With GSM communicator (optional).
  4. It can be integrated to any GSM dialer.
  5. Operates on 220V, 50 Hz A.C supply.
  6. Battery backup with built in charging.
  7. 16 x 2 LCD to show the condition of the system.
  8. Zone addressing can be done.
  9. Error free Fire / Fault status in unambiguous colored LED indication. And same will be displayed in LCD.
  10. Low battery, Battery Fail visual warning with audible tone.
    System on, AC on, Battery on indications.
  11. Relay (Dry Contact) output for actuators.
    Lamp test facility.
    Compatible to all types of conventional detectors.
  12. Twin RED LED indication for fire.
  13. Zone Disable (Isolation) facility with loop voltage cut off.
  14. Resettable 24v DC output for 4 wire detectors (Optional).
  15. Product is tested and approved by ETDC (Electronic Test and Development Center) Ministry of Electronics and Information Technology, Government of India.
MCN-GSM
VARIANTS AVAILABLE

08 Zone Intrusion

Note:

The product will be discontinued from 01.04.2024 the new model launch will be informed shortly. The service backup for the model will be available for next 3 years.

Our panel has the following features with very friendly user interface. It may be noted these are standard features as per the industry requirement but can be modified as per the client/customer requirement.

Specifications

  1. Rugged CRCA sheet with powder coated finish.
  2. Modular construction.
  3. With GSM communicator
  4. Panel can be remotely controlled by the registered user in the control panel for Reset, Silence.
  5. 16 x 2 LCD to show the condition of the system.
  6. Zone addressing can be done.
  7. 200 events will be stored in the panel.
  8. Error free Fire / Fault status in unambiguous colored
  9. LED indication. And same will be displayed in LCD.
  10. Low battery, Battery Fail visual warning with audible tone.
  11. System on, AC on, Battery on indications.
  12. Relay (Dry Contact) output for actuators.
    Remote fire indication with Audible Tone.
  13. Lamp test facility.
    Compatible to all types of conventional detectors.
  14. Twin RED LED indication for fire.
  15. Operates on 220V, 50 Hz A.C supply.
  16. Battery backup with built in charging.
  17. Zone Disable (Isolation) facility with loop voltage cut off.
  18. Resettable 24v DC output for 4 wire detectors (Optional).
  19. Product is tested and approved by ETDC (Electronic Test and Development Center) Ministry of Electronics and Information Technology, Government of India.
Note:

 The product will be discontinued from 01.04.2024 the new model launchwill be informed shortly. The service backup for the model will beavailable for next 3 years.

Cart

No products in the cart.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare